Response Summary View
Contains information summarizing the results of the Reflective Cracking Phase testing cycles, including Sensor id, sensor name, sensor type, test section id, cycle number, response, response value and response time. Below are the column names and descriptions to query the RC database for Phase VI.
 
The testing parameters for Phase VI are as follows: Target temperature at overlay bottom 32 ºF,
maximum joint opening 12 mils, (12 x 10-3 in), cycle time 150 seconds and rest period 600 seconds. 
    
    
        
            | dbo.Response6 | 
        
            | SensorID | Sequential number used for sensor identification | 
        
            | SensorName  | Name assigned to the sensor. The first letters identify the sensor type:    POT = Potentiometer LVDT = Linear Variable Differential Transducer JDG = Joint Displacement Gage EG = Embedded Strain Gage SG = Surface Strain Gage  T = Thermocouple  NORTH LOAD CELL SOUTH LOAD CELL | 
        
            | SensorType  | Displacement mils(inches x 10-3), Microstrain (strain x 10-6), Temperature (ºF)
   | 
        
            | TestSectionID   | Unique number assigned to identify each of the two test sections.  1= North and 2 = South    | 
        
            | CycleNum | The number of the cycle. | 
        
            | ResponseType (sensor response)      | OL = offset left (first reading) MRL = Minimum Response Left MR = Maximum Response MRR = Minimum Response Right OR = Offset Right | 
        
            | ResponseValue | The value associated with the response. | 
        
            | ResponseTime | The time associated with the response. | 
        
            | TestParameterID | Unique id associated with the specific testing parameters for the corresponding phase  | 
    
 
Sample Strain Gage Response