Response Summary View
Contains information summarizing the results of the Reflective Cracking Phase testing cycles, including Sensor id, sensor name, sensor type, test section id, cycle number, response, response value, and response time. Below are the column names and descriptions to query the RC database for Phase IV.
The testing parameters for Phase IV are as follows: Target temperature at overlay bottom 32 ºF, maximum joint opening 12 mils, (12 x 10-3 in), cycle time 150 seconds and rest period 600 seconds.
    
    
        
            |  dbo.Response4 | 
        
        
            SensorID 
             | 
            Sequential number used for sensor identification. 
             | 
        
        
            SensorName 
             | 
            Name assigned to the sensor. The first letters identify the sensor type: 
             
             
            POT = Potentiometer 
            LVDT = Linear Variable Differential Transducer 
            JDG = Joint Displacement Gage 
            EG = Embedded Strain Gage 
            SG = Surface Strain Gage 
            T = Thermocouple 
            NORTH LOAD CELL 
            SOUTH LOAD CELL 
             
             | 
        
        
            | SensorType | 
            Temperature (ºF), Microstrain (strain x 10-6), Displacement mils (inches x 10-3), Force (lbs) | 
        
        
            | 
             TestSectionID  
             | 
            
             Unique number assigned to identify each of the two test sections.   
            1 = North and 2 = South 
             | 
        
        
            | 
             CycleNum 
             | 
            
             The number of the cycle. 
             | 
        
        
            | 
             ResponseType 
            (sensor response) 
             
             
            Refer to "Sample Strain Gage Response" image below 
             | 
            
             OL = offset left (first reading) 
            MRL = Minimum Response Left 
            MR = Maximum Response 
            MRR = Minimum Response Right 
            OR = Offset Right 
             | 
        
        
            ResponseValue 
             | 
            The value associated with the response. | 
        
        
            ResponseTime 
             | 
            The time associated with the response.  | 
        
        
            TestParameterID 
             | 
            Unique id associated with the specific testing parameters for the corresponding phase. | 
        
    
 
Sample Strain Gage Response