Sensor

Sensor Table

The Sensor Table includes all of the information related to the sensors used in the testing. It includes the names, types and location of the sensors. 


The Calibration Factors were used during data processing to convert voltages acquired into engineering units for each type of sensor. They are included in the database for completeness. 


 For more information about the CC8 Phase 1 Overload sensors, click here. 

 

TestItem Location of test area (north or south).
SlabID Name associated with the test section item number

SensorID

Number used for sensor identification

SensorName

Name assigned to the sensor. The first letters identify the sensor type

SensorType

Information such as full bridge, vertical displacement, and deflection

Unit

Units the sensors record in

GageType

Returns thermocouple, moisture sensors, embedded gage, potentiometer, and eddy current sensors

LocationX_FT

Sensor location X coordinate in feet from Instrumentation Plan

LocationY_FT

Sensor location Y coordinate in feet from Instrumentation Plan

LocationZ_N

Sensor location Z coordinate in inches from Instrumentation Plan

Calibration Factor 1 Parameters used during data processing, includes sensor position as well as sensor scaling and offset values
Calibration Factor 2 Parameters used during data processing, includes sensor position as well as sensor scaling and offset values
Calibration Factor 3 Parameters used during data processing, includes sensor position as well as sensor scaling and offset values
Calibration Factor 4 Parameters used during data processing, includes sensor position as well as sensor scaling and offset values
Calibration Factor 5 Parameters used during data processing, includes sensor position as well as sensor scaling and offset values
Calibration Factor 6 Parameters used during data processing, includes sensor position as well as sensor scaling and offset values
SPUNo Number of the Signal Processing Unit (SPU) used to acquire dynamic data from SenosrName
Card Pertains to physical DAQ connection

Channel

Pertains to physical DAQ connection

Channel Status

Pertains to physical DAQ connection – 1 is collect, 0 is no collection

Mux

Number assigned to the multiplexer (MUX) used to acquire static data from SensorName

PhaseID

Test section number

 

Return to Search CC8 Phase 1 Database 

 


 

Query Sensor Data

TestItemSlabIDSensorIDSensorNameSensorTypeUnitGageTypeLocationX_FTLocationY_FTLocationZ_FTDepth_INCalibration Factor 1Calibration Factor 2Calibration Factor 3Calibration Factor 4Calibration Factor 5Calibration Factor 6SPUNoCardChannelChannel StatusPhaseIDMUX
North1N83102EG-N-O-I-3Full Bridge microstrainEmbedded Gage342.25-11.0057.0811.00728.75561342.25-111131211 
North1N83103EG-N-O-I-4Full Bridge microstrainEmbedded Gage342.25-11.0056.5018.00745561342.25-111831311 
South1S83122EG-S-O-I-3Full Bridge microstrainEmbedded Gage342.2511.0057.0811.00703.75571342.251111311011 
South1S83123EG-S-O-I-4Full Bridge microstrainEmbedded Gage342.2511.0056.5018.00763.5571342.251118311111 
North2N83106EG-N-O-I-7Full Bridge microstrainEmbedded Gage346.00-14.7557.0811.00675561346-14.751131611 
North2N83107EG-N-O-I-8Full Bridge microstrainEmbedded Gage346.00-14.7556.5018.00736.25561346-14.751831711 
South2S83126EG-S-O-I-7Full Bridge microstrainEmbedded Gage346.0014.7557.0811.00730.557134614.7511311411 
South2S83127EG-S-O-I-8Full Bridge microstrainEmbedded Gage346.0014.7556.5018.00753.557134614.7518311511 
North3N83117POT-N-O-I-2Vertical Displacement milsPotentiometer354.25-14.7556.4219.001000584.623354.25-14.7519311711 
South3S83137POT-S-O-I-2Vertical Displacement milsPotentiometer354.2514.7556.4219.001000583.223354.2514.7519312111 
1 2 3 4 5 6